Distribution Transformers
For utility, commercial and industrial distribution networks that need the right capacity, efficiency and site configuration.

APPLICATION
Specified for the work it needs to do.
A distribution transformer must suit the network and its operating pattern. We review the specification, efficiency target and local utility requirements before identifying an appropriate production option.
Common applications
- Utility distribution networks
- Industrial facilities
- Commercial power distribution
PRODUCT CAPABILITIES
Published 10 kV distribution families.
Our manufacturing partners offer oil-immersed S13-M, S20-M and S22-M sealed units; S13-M·RL, S20-M·RL and S22-M·RL three-dimensional wound-core units; and SH/SBH15-M, SH/SBH21-M and SH/SBH25-M amorphous-core variants.
EU Ecodesign scope and Tier 2 →MANUFACTURER CATALOGUE TABLES
10 kV distribution transformer technical data
Compare the 10 kV distribution transformer models below. The tables preserve catalogue losses and show how ratings vary by series.
S13-M · Oil-immersed, fully sealed19 ratings · click to view
Primary voltage options in the source: 6, 6.3, 10, 10.5 and 11 kV; secondary: 0.4 kV. For ratings up to 500 kVA, load-loss values separated by a slash are published as Dyn11 / Yyn0. Confirm the applicable value for the quoted vector group.
| Model | kVA | No-load loss W | Load loss W | No-load current % | Impedance % |
|---|---|---|---|---|---|
| S13-M-30/10 | 30 | 80 | 630/600 | 1.2 | 4 |
| S13-M-50/10 | 50 | 100 | 910/870 | 1.04 | 4 |
| S13-M-63/10 | 63 | 110 | 1090/1040 | 0.96 | 4 |
| S13-M-80/10 | 80 | 130 | 1310/1250 | 0.96 | 4 |
| S13-M-100/10 | 100 | 150 | 1580/1500 | 0.88 | 4 |
| S13-M-125/10 | 125 | 170 | 1890/1800 | 0.88 | 4 |
| S13-M-160/10 | 160 | 200 | 2310/2200 | 0.8 | 4 |
| S13-M-200/10 | 200 | 240 | 2730/2600 | 0.8 | 4 |
| S13-M-250/10 | 250 | 290 | 3200/3050 | 0.72 | 4 |
| S13-M-315/10 | 315 | 340 | 3830/3650 | 0.72 | 4 |
| S13-M-400/10 | 400 | 410 | 4520/4300 | 0.64 | 4 |
| S13-M-500/10 | 500 | 480 | 5410/5150 | 0.64 | 4 |
| S13-M-630/10 | 630 | 570 | 6200 | 0.48 | 4.5 |
| S13-M-800/10 | 800 | 700 | 7500 | 0.48 | 4.5 |
| S13-M-1000/10 | 1000 | 830 | 10300 | 0.48 | 4.5 |
| S13-M-1250/10 | 1250 | 970 | 12000 | 0.4 | 4.5 |
| S13-M-1600/10 | 1600 | 1170 | 14500 | 0.4 | 4.5 |
| S13-M-2000/10 | 2000 | 1360 | 18300 | 0.32 | 5 |
| S13-M-2500/10 | 2500 | 1600 | 21200 | 0.32 | 5 |
S20-M · Oil-immersed, fully sealed19 ratings · click to view
Primary voltage options in the source: 6, 6.3, 10, 10.5 and 11 kV; secondary: 0.4 kV. For ratings up to 500 kVA, load-loss values separated by a slash are published as Dyn11 / Yyn0. Confirm the applicable value for the quoted vector group.
| Model | kVA | No-load loss W | Load loss W | No-load current % | Impedance % |
|---|---|---|---|---|---|
| S20-M-30/10 | 30 | 70 | 505/480 | 1.2 | 4 |
| S20-M-50/10 | 50 | 90 | 730/695 | 1.04 | 4 |
| S20-M-63/10 | 63 | 100 | 870/830 | 0.96 | 4 |
| S20-M-80/10 | 80 | 115 | 1050/1000 | 0.96 | 4 |
| S20-M-100/10 | 100 | 135 | 1265/1200 | 0.88 | 4 |
| S20-M-125/10 | 125 | 150 | 1510/1440 | 0.88 | 4 |
| S20-M-160/10 | 160 | 180 | 1850/1760 | 0.8 | 4 |
| S20-M-200/10 | 200 | 215 | 2185/2080 | 0.8 | 4 |
| S20-M-250/10 | 250 | 260 | 2560/2440 | 0.72 | 4 |
| S20-M-315/10 | 315 | 305 | 3065/2920 | 0.72 | 4 |
| S20-M-400/10 | 400 | 370 | 3615/3440 | 0.64 | 4 |
| S20-M-500/10 | 500 | 430 | 4330/4120 | 0.64 | 4 |
| S20-M-630/10 | 630 | 510 | 4960 | 0.48 | 4.5 |
| S20-M-800/10 | 800 | 630 | 6000 | 0.48 | 4.5 |
| S20-M-1000/10 | 1000 | 745 | 8240 | 0.48 | 4.5 |
| S20-M-1250/10 | 1250 | 870 | 9600 | 0.4 | 4.5 |
| S20-M-1600/10 | 1600 | 1050 | 11600 | 0.4 | 4.5 |
| S20-M-2000/10 | 2000 | 1225 | 14640 | 0.32 | 5 |
| S20-M-2500/10 | 2500 | 1440 | 16960 | 0.32 | 5 |
S22-M · Oil-immersed, fully sealed19 ratings · click to view
Primary voltage options in the source: 6, 6.3, 10, 10.5 and 11 kV; secondary: 0.4 kV. For ratings up to 500 kVA, load-loss values separated by a slash are published as Dyn11 / Yyn0. Confirm the applicable value for the quoted vector group.
| Model | kVA | No-load loss W | Load loss W | No-load current % | Impedance % |
|---|---|---|---|---|---|
| S22-M-30/10 | 30 | 65 | 455/430 | 1.2 | 4 |
| S22-M-50/10 | 50 | 80 | 655/625 | 1.04 | 4 |
| S22-M-63/10 | 63 | 90 | 785/745 | 0.96 | 4 |
| S22-M-80/10 | 80 | 105 | 945/900 | 0.96 | 4 |
| S22-M-100/10 | 100 | 120 | 1140/1080 | 0.88 | 4 |
| S22-M-125/10 | 125 | 135 | 1360/1295 | 0.88 | 4 |
| S22-M-160/10 | 160 | 160 | 1665/1585 | 0.8 | 4 |
| S22-M-200/10 | 200 | 190 | 1970/1870 | 0.8 | 4 |
| S22-M-250/10 | 250 | 230 | 2300/2195 | 0.72 | 4 |
| S22-M-315/10 | 315 | 270 | 2760/2630 | 0.72 | 4 |
| S22-M-400/10 | 400 | 330 | 3250/3095 | 0.64 | 4 |
| S22-M-500/10 | 500 | 385 | 3900/3710 | 0.64 | 4 |
| S22-M-630/10 | 630 | 460 | 4460 | 0.48 | 4.5 |
| S22-M-800/10 | 800 | 560 | 5400 | 0.48 | 4.5 |
| S22-M-1000/10 | 1000 | 665 | 7415 | 0.48 | 4.5 |
| S22-M-1250/10 | 1250 | 780 | 8640 | 0.4 | 4.5 |
| S22-M-1600/10 | 1600 | 940 | 10440 | 0.4 | 4.5 |
| S22-M-2000/10 | 2000 | 1085 | 13180 | 0.32 | 5 |
| S22-M-2500/10 | 2500 | 1280 | 15270 | 0.32 | 5 |
S13-M·RL · Three-dimensional wound core19 ratings · click to view
Primary voltage options in the source: 6, 6.3, 10, 10.5 and 11 kV; secondary: 0.4 kV. For ratings up to 500 kVA, load-loss values separated by a slash are published as Dyn11 / Yyn0. Confirm the applicable value for the quoted vector group.
| Model | kVA | No-load loss W | Load loss W | No-load current % | Impedance % |
|---|---|---|---|---|---|
| S13-M·RL-30/10 | 30 | 80 | 630/600 | 1.2 | 4 |
| S13-M·RL-50/10 | 50 | 100 | 910/870 | 1.04 | 4 |
| S13-M·RL-63/10 | 63 | 110 | 1090/1040 | 0.96 | 4 |
| S13-M·RL-80/10 | 80 | 130 | 1310/1250 | 0.96 | 4 |
| S13-M·RL-100/10 | 100 | 150 | 1580/1500 | 0.88 | 4 |
| S13-M·RL-125/10 | 125 | 170 | 1890/1800 | 0.88 | 4 |
| S13-M·RL-160/10 | 160 | 200 | 2310/2200 | 0.8 | 4 |
| S13-M·RL-200/10 | 200 | 240 | 2730/2600 | 0.8 | 4 |
| S13-M·RL-250/10 | 250 | 290 | 3200/3050 | 0.72 | 4 |
| S13-M·RL-315/10 | 315 | 340 | 3830/3650 | 0.72 | 4 |
| S13-M·RL-400/10 | 400 | 410 | 4520/4300 | 0.64 | 4 |
| S13-M·RL-500/10 | 500 | 480 | 5410/5150 | 0.64 | 4 |
| S13-M·RL-630/10 | 630 | 570 | 6200 | 0.48 | 4.5 |
| S13-M·RL-800/10 | 800 | 700 | 7500 | 0.48 | 4.5 |
| S13-M·RL-1000/10 | 1000 | 830 | 10300 | 0.48 | 4.5 |
| S13-M·RL-1250/10 | 1250 | 970 | 12000 | 0.4 | 4.5 |
| S13-M·RL-1600/10 | 1600 | 1170 | 14500 | 0.4 | 4.5 |
| S13-M·RL-2000/10 | 2000 | 1360 | 18300 | 0.32 | 5 |
| S13-M·RL-2500/10 | 2500 | 1600 | 21200 | 0.32 | 5 |
S20-M·RL · Three-dimensional wound core19 ratings · click to view
Primary voltage options in the source: 6, 6.3, 10, 10.5 and 11 kV; secondary: 0.4 kV. For ratings up to 500 kVA, load-loss values separated by a slash are published as Dyn11 / Yyn0. Confirm the applicable value for the quoted vector group.
| Model | kVA | No-load loss W | Load loss W | No-load current % | Impedance % |
|---|---|---|---|---|---|
| S20-M·RL-30/10 | 30 | 70 | 505/480 | 1.2 | 4 |
| S20-M·RL-50/10 | 50 | 90 | 730/695 | 1.04 | 4 |
| S20-M·RL-63/10 | 63 | 100 | 870/830 | 0.96 | 4 |
| S20-M·RL-80/10 | 80 | 115 | 1050/1000 | 0.96 | 4 |
| S20-M·RL-100/10 | 100 | 135 | 1265/1200 | 0.88 | 4 |
| S20-M·RL-125/10 | 125 | 150 | 1510/1440 | 0.88 | 4 |
| S20-M·RL-160/10 | 160 | 180 | 1850/1760 | 0.8 | 4 |
| S20-M·RL-200/10 | 200 | 215 | 2185/2080 | 0.8 | 4 |
| S20-M·RL-250/10 | 250 | 260 | 2560/2440 | 0.72 | 4 |
| S20-M·RL-315/10 | 315 | 305 | 3065/2920 | 0.72 | 4 |
| S20-M·RL-400/10 | 400 | 370 | 3615/3440 | 0.64 | 4 |
| S20-M·RL-500/10 | 500 | 430 | 4330/4120 | 0.64 | 4 |
| S20-M·RL-630/10 | 630 | 510 | 4960 | 0.48 | 4.5 |
| S20-M·RL-800/10 | 800 | 630 | 6000 | 0.48 | 4.5 |
| S20-M·RL-1000/10 | 1000 | 745 | 8240 | 0.48 | 4.5 |
| S20-M·RL-1250/10 | 1250 | 870 | 9600 | 0.4 | 4.5 |
| S20-M·RL-1600/10 | 1600 | 1050 | 11600 | 0.4 | 4.5 |
| S20-M·RL-2000/10 | 2000 | 1225 | 14640 | 0.32 | 5 |
| S20-M·RL-2500/10 | 2500 | 1440 | 16960 | 0.32 | 5 |
S22-M·RL · Three-dimensional wound core19 ratings · click to view
Primary voltage options in the source: 6, 6.3, 10, 10.5 and 11 kV; secondary: 0.4 kV. For ratings up to 500 kVA, load-loss values separated by a slash are published as Dyn11 / Yyn0. Confirm the applicable value for the quoted vector group.
| Model | kVA | No-load loss W | Load loss W | No-load current % | Impedance % |
|---|---|---|---|---|---|
| S22-M·RL-30/10 | 30 | 65 | 455/430 | 1.2 | 4 |
| S22-M·RL-50/10 | 50 | 80 | 655/625 | 1.04 | 4 |
| S22-M·RL-63/10 | 63 | 90 | 785/745 | 0.96 | 4 |
| S22-M·RL-80/10 | 80 | 105 | 945/900 | 0.96 | 4 |
| S22-M·RL-100/10 | 100 | 120 | 1140/1080 | 0.88 | 4 |
| S22-M·RL-125/10 | 125 | 135 | 1360/1295 | 0.88 | 4 |
| S22-M·RL-160/10 | 160 | 160 | 1665/1585 | 0.8 | 4 |
| S22-M·RL-200/10 | 200 | 190 | 1970/1870 | 0.8 | 4 |
| S22-M·RL-250/10 | 250 | 230 | 2300/2195 | 0.72 | 4 |
| S22-M·RL-315/10 | 315 | 270 | 2760/2630 | 0.72 | 4 |
| S22-M·RL-400/10 | 400 | 330 | 3250/3095 | 0.64 | 4 |
| S22-M·RL-500/10 | 500 | 385 | 3900/3710 | 0.64 | 4 |
| S22-M·RL-630/10 | 630 | 460 | 4460 | 0.48 | 4.5 |
| S22-M·RL-800/10 | 800 | 560 | 5400 | 0.48 | 4.5 |
| S22-M·RL-1000/10 | 1000 | 665 | 7415 | 0.48 | 4.5 |
| S22-M·RL-1250/10 | 1250 | 780 | 8640 | 0.4 | 4.5 |
| S22-M·RL-1600/10 | 1600 | 940 | 10440 | 0.4 | 4.5 |
| S22-M·RL-2000/10 | 2000 | 1085 | 13180 | 0.32 | 5 |
| S22-M·RL-2500/10 | 2500 | 1280 | 15270 | 0.32 | 5 |
SH15-M · Amorphous alloy core4 ratings · click to view
Primary voltage options in the source: 6, 6.3, 10, 10.5 and 11 kV; secondary: 0.4 kV. For ratings up to 500 kVA, load-loss values separated by a slash are published as Dyn11 / Yyn0. Confirm the applicable value for the quoted vector group.
| Model | kVA | No-load loss W | Load loss W | No-load current % | Impedance % |
|---|---|---|---|---|---|
| SH15-M-30 | 30 | 33 | 630/600 | 1.5 | 4 |
| SH15-M-50 | 50 | 43 | 910/870 | 1.2 | 4 |
| SH15-M-63 | 63 | 50 | 1090/1040 | 1.1 | 4 |
| SH15-M-80 | 80 | 60 | 1310/1250 | 1 | 4 |
SBH15-M · Amorphous alloy core15 ratings · click to view
Primary voltage options in the source: 6, 6.3, 10, 10.5 and 11 kV; secondary: 0.4 kV. For ratings up to 500 kVA, load-loss values separated by a slash are published as Dyn11 / Yyn0. Confirm the applicable value for the quoted vector group.
| Model | kVA | No-load loss W | Load loss W | No-load current % | Impedance % |
|---|---|---|---|---|---|
| SBH15-M-100 | 100 | 75 | 1580/1500 | 0.9 | — |
| SBH15-M-125 | 125 | 85 | 1890/1800 | 0.8 | — |
| SBH15-M-160 | 160 | 100 | 2310/2200 | 0.6 | — |
| SBH15-M-200 | 200 | 120 | 2730/2600 | 0.6 | — |
| SBH15-M-250 | 250 | 140 | 3200/3050 | 0.6 | — |
| SBH15-M-315 | 315 | 170 | 3830/3650 | 0.5 | — |
| SBH15-M-400 | 400 | 200 | 4520/4300 | 0.5 | — |
| SBH15-M-500 | 500 | 240 | 5410/5150 | 0.5 | — |
| SBH15-M-630 | 630 | 320 | 6200 | 0.3 | 4.5 |
| SBH15-M-800 | 800 | 380 | 7500 | 0.3 | 4.5 |
| SBH15-M-1000 | 1000 | 450 | 10300 | 0.3 | 4.5 |
| SBH15-M-1250 | 1250 | 530 | 12000 | 0.2 | 4.5 |
| SBH15-M-1600 | 1600 | 630 | 14500 | 0.2 | 4.5 |
| SBH15-M-2000 | 2000 | 720 | 18300 | 0.2 | 5.5 |
| SBH15-M-2500 | 2500 | 865 | 21200 | 0.2 | 5.5 |
SH21-M · Amorphous alloy core4 ratings · click to view
Primary voltage options in the source: 6, 6.3, 10, 10.5 and 11 kV; secondary: 0.4 kV. For ratings up to 500 kVA, load-loss values separated by a slash are published as Dyn11 / Yyn0. Confirm the applicable value for the quoted vector group.
| Model | kVA | No-load loss W | Load loss W | No-load current % | Impedance % |
|---|---|---|---|---|---|
| SH21-M-30 | 30 | 33 | 535/510 | 1.5 | 4 |
| SH21-M-50 | 50 | 43 | 780/745 | 1.2 | 4 |
| SH21-M-63 | 63 | 50 | 930/890 | 1.1 | 4 |
| SH21-M-80 | 80 | 60 | 1120/1070 | 1 | 4 |
SBH21-M · Amorphous alloy core15 ratings · click to view
Primary voltage options in the source: 6, 6.3, 10, 10.5 and 11 kV; secondary: 0.4 kV. For ratings up to 500 kVA, load-loss values separated by a slash are published as Dyn11 / Yyn0. Confirm the applicable value for the quoted vector group.
| Model | kVA | No-load loss W | Load loss W | No-load current % | Impedance % |
|---|---|---|---|---|---|
| SBH21-M-100 | 100 | 75 | 1350/1285 | 0.9 | — |
| SBH21-M-125 | 125 | 85 | 1615/1540 | 0.8 | — |
| SBH21-M-160 | 160 | 100 | 1975/1880 | 0.6 | — |
| SBH21-M-200 | 200 | 120 | 2330/2225 | 0.6 | — |
| SBH21-M-250 | 250 | 140 | 2735/2610 | 0.6 | — |
| SBH21-M-315 | 315 | 170 | 3275/3120 | 0.5 | — |
| SBH21-M-400 | 400 | 200 | 3865/3675 | 0.5 | — |
| SBH21-M-500 | 500 | 240 | 4625/4400 | 0.5 | — |
| SBH21-M-630 | 630 | 320 | 5300 | 0.3 | 4.5 |
| SBH21-M-800 | 800 | 380 | 6415 | 0.3 | 4.5 |
| SBH21-M-1000 | 1000 | 450 | 8800 | 0.3 | 4.5 |
| SBH21-M-1250 | 1250 | 530 | 10260 | 0.2 | 4.5 |
| SBH21-M-1600 | 1600 | 630 | 12400 | 0.2 | 4.5 |
| SBH21-M-2000 | 2000 | 710 | 14800 | 0.2 | 5 |
| SBH21-M-2500 | 2500 | 860 | 17150 | 0.2 | 5 |
SH25-M · Amorphous alloy core4 ratings · click to view
Primary voltage options in the source: 6, 6.3, 10, 10.5 and 11 kV; secondary: 0.4 kV. For ratings up to 500 kVA, load-loss values separated by a slash are published as Dyn11 / Yyn0. Confirm the applicable value for the quoted vector group.
| Model | kVA | No-load loss W | Load loss W | No-load current % | Impedance % |
|---|---|---|---|---|---|
| SH25-M-30 | 30 | 25 | 510/480 | 1.5 | 4 |
| SH25-M-50 | 50 | 35 | 735/700 | 1.2 | 4 |
| SH25-M-63 | 63 | 40 | 880/840 | 1.1 | 4 |
| SH25-M-80 | 80 | 50 | 1060/1010 | 1 | 4 |
SBH25-M · Amorphous alloy core15 ratings · click to view
Primary voltage options in the source: 6, 6.3, 10, 10.5 and 11 kV; secondary: 0.4 kV. For ratings up to 500 kVA, load-loss values separated by a slash are published as Dyn11 / Yyn0. Confirm the applicable value for the quoted vector group.
| Model | kVA | No-load loss W | Load loss W | No-load current % | Impedance % |
|---|---|---|---|---|---|
| SBH25-M-100 | 100 | 60 | 1270/1215 | 0.9 | — |
| SBH25-M-125 | 125 | 70 | 1530/1450 | 0.8 | — |
| SBH25-M-160 | 160 | 80 | 1870/1780 | 0.6 | — |
| SBH25-M-200 | 200 | 95 | 2210/2100 | 0.6 | — |
| SBH25-M-250 | 250 | 110 | 2590/2470 | 0.6 | — |
| SBH25-M-315 | 315 | 135 | 3100/2950 | 0.5 | — |
| SBH25-M-400 | 400 | 160 | 3660/3480 | 0.5 | — |
| SBH25-M-500 | 500 | 190 | 4380/4170 | 0.5 | — |
| SBH25-M-630 | 630 | 250 | 5020 | 0.3 | 4.5 |
| SBH25-M-800 | 800 | 300 | 6075 | 0.3 | 4.5 |
| SBH25-M-1000 | 1000 | 360 | 8340 | 0.3 | 4.5 |
| SBH25-M-1250 | 1250 | 425 | 9720 | 0.2 | 4.5 |
| SBH25-M-1600 | 1600 | 500 | 11745 | 0.2 | 4.5 |
| SBH25-M-2000 | 2000 | 550 | 14000 | 0.2 | 5 |
| SBH25-M-2500 | 2500 | 670 | 16230 | 0.2 | 5 |
The manufacturer confirms final loss values for the selected model. EU or U.S. compliance must be established from the applicable configuration, frequency, test method and current signed data sheet.
PROJECT INQUIRY
What helps us review your requirement.
A data sheet or single-line diagram is the best starting point. If some information is missing, send what you have.
- Electrical ratings
- Capacity, primary and secondary voltage, phase and frequency
- Installation
- Indoor or outdoor location, footprint and environmental conditions
- Efficiency
- Loss limits and applicable local efficiency rules
- Project evidence
- Utility specification, required approvals, tests and delivery date