Power Transformers
For transmission, generation and large industrial connections where electrical duty, site conditions and test evidence must be aligned before production.

APPLICATION
Specified for the work it needs to do.
Large power transformers are specified around the network they serve. WEYPLEX coordinates the incoming data sheet with a suitable manufacturer, then confirms the proposed design and documentation for that model.
Common applications
- Utility transmission and substations
- Power generation connections
- Large industrial power systems
- Data center substations
PRODUCT CAPABILITIES
Power transformer voltage classes
Our manufacturing partners offer power transformer families in 35 kV, 110 kV, 220 kV, 330 kV and 500 kV classes. We confirm the ratings and applicable certifications for the quoted model.
EU large-transformer efficiency is assessed using the applicable Peak Efficiency Index; U.S. requirements depend on equipment scope and project specifications. We verify the applicable efficiency requirements for the quoted model.
MANUFACTURER CATALOGUE TABLES
Power transformer catalogue ratings
Compare representative 22-series loss values across the five voltage classes. Final values depend on the selected design.
35 kV · 22 series · three-phase, double-winding15 ratings · click to view
One published configuration from the manufacturer's voltage-class document. No-load and load losses are expressed in kW. Other winding, tapping and voltage combinations have separate values in the original file and require a project-specific data sheet.
| Rated capacity kVA | No-load loss kW | Load loss kW | No-load current % | Impedance % |
|---|---|---|---|---|
| 3150 | 1.7 | 20.7 | 0.45 | 7.0 |
| 4000 | 2.0 | 24.6 | 0.45 | 7.0 |
| 5000 | 2.4 | 28.2 | 0.45 | 7.0 |
| 6300 | 2.9 | 31.5 | 0.45 | 8.0 |
| 8000 | 4.0 | 34.6 | 0.35 | 8.0 |
| 10000 | 4.8 | 40.8 | 0.35 | 8.0 |
| 12500 | 5.5 | 48.4 | 0.30 | 8.0 |
| 16000 | 6.7 | 59.2 | 0.30 | 8.0 |
| 20000 | 7.9 | 71.6 | 0.30 | 8.0 |
| 25000 | 9.4 | 84.6 | 0.25 | 10.0 |
| 31500 | 11.1 | 100.8 | 0.25 | 10.0 |
| 40000 | 12.6 | 122.5 | 0.20 | 12~15 |
| 50000 | 14.8 | 145.1 | 0.20 | 12~15 |
| 63000 | 17.1 | 175.7 | 0.20 | 12~15 |
| 75000 | 19.3 | 229.7 | 0.20 | 12~15 |
110 kV · 22 series · three-phase, double-winding16 ratings · click to view
One published configuration from the manufacturer's voltage-class document. No-load and load losses are expressed in kW. Other winding, tapping and voltage combinations have separate values in the original file and require a project-specific data sheet.
| Rated capacity kVA | No-load loss kW | Load loss kW | No-load current % | Impedance % |
|---|---|---|---|---|
| 6300 | 4.1 | 32 | 0.3 | 10.5 |
| 8000 | 4.9 | 38 | 0.3 | 10.5 |
| 10000 | 5.8 | 45 | 0.3 | 10.5 |
| 12500 | 6.8 | 53 | 0.3 | 10.5 |
| 16000 | 8.3 | 65.7 | 0.3 | 10.5 |
| 20000 | 9.7 | 79 | 0.3 | 10.5 |
| 25000 | 11.4 | 94 | 0.25 | 10.5 |
| 31500 | 13.5 | 111 | 0.25 | 10.5 |
| 40000 | 16.2 | 133 | 0.25 | 10.5 |
| 50000 | 19.4 | 158 | 0.25 | 10.5 |
| 63000 | 22.9 | 187 | 0.2 | 10.5 |
| 75000 | 26.0 | 212 | 0.2 | 12~14 |
| 90000 | 29.9 | 245 | 0.2 | 12~14 |
| 120000 | 37.3 | 303 | 0.2 | 12~14 |
| 150000 | 44.1 | 359 | 0.18 | 12~14 |
| 180000 | 49.5 | 411 | 0.18 | 12~14 |
220 kV · 22 series · three-phase, double-winding16 ratings · click to view
One published configuration from the manufacturer's voltage-class document. No-load and load losses are expressed in kW. Other winding, tapping and voltage combinations have separate values in the original file and require a project-specific data sheet.
| Rated capacity kVA | No-load loss kW | Load loss kW | No-load current % | Impedance % |
|---|---|---|---|---|
| 31500 | 15 | 115 | 0.3 | 12~14 |
| 40000 | 18 | 134 | 0.3 | 12~14 |
| 50000 | 21 | 161 | 0.3 | 12~14 |
| 63000 | 25 | 188 | 0.3 | 12~14 |
| 75000 | 29 | 213 | 0.3 | 12~14 |
| 90000 | 34 | 246 | 0.3 | 12~14 |
| 120000 | 41 | 304 | 0.25 | 12~14 |
| 150000 | 49 | 360 | 0.25 | 12~14 |
| 160000 | 51 | 378 | 0.25 | 12~14 |
| 180000 | 56 | 413 | 0.25 | 12~14 |
| 240000 | 70 | 484 | 0.2 | 12~14 |
| 300000 | 83 | 577 | 0.2 | 12~14 |
| 360000 | 95 | 662 | 0.2 | 12~14 |
| 370000 | 97 | 675 | 0.2 | 12~14 |
| 400000 | 103 | 716 | 0.18 | 12~14 |
| 420000 | 106 | 742 | 0.18 | 12~14 |
330 kV · 22 series · three-phase, double-winding9 ratings · click to view
One published configuration from the manufacturer's voltage-class document. No-load and load losses are expressed in kW. Other winding, tapping and voltage combinations have separate values in the original file and require a project-specific data sheet.
| Rated capacity kVA | No-load loss kW | Load loss kW | No-load current % | Impedance % |
|---|---|---|---|---|
| 90000 | 37 | 247 | 0.28 | 14~15 |
| 120000 | 47 | 306 | 0.28 | 14~15 |
| 150000 | 56 | 362 | 0.26 | 14~15 |
| 180000 | 64 | 415 | 0.24 | 14~15 |
| 240000 | 80 | 515 | 0.22 | 14~15 |
| 360000 | 109 | 722 | 0.22 | 14~15 |
| 370000 | 111 | 736 | 0.19 | 14~15 |
| 400000 | 118 | 780 | 0.19 | 14~15 |
| 720000 | 183 | 1212 | 0.25 | 14~15 |
500 kV · 22 series · three-phase, double-winding15 ratings · click to view
One published configuration from the manufacturer's voltage-class document. No-load and load losses are expressed in kW. Other winding, tapping and voltage combinations have separate values in the original file and require a project-specific data sheet.
| Rated capacity kVA | No-load loss kW | Load loss kW | No-load current % | Impedance % |
|---|---|---|---|---|
| 120000 | 41 | 356 | 0.13 | 14 |
| 160000 | 50 | 441 | 0.13 | 14 |
| 240000 | 69 | 599 | 0.1 | 14 |
| 300000 | 80 | 707 | 0.1 | 14 |
| 370000 | 94 | 810 | 0.08 | 14 |
| 400000 | 96 | 855 | 0.08 | 14 |
| 420000 | 102 | 860 | 0.08 | 14或16 |
| 480000 | 110 | 954 | 0.08 | 14或16 |
| 600000 | 143 | 1202 | 0.08 | 14或16 |
| 720000 | 168 | 1382 | 0.08 | 14或16 |
| 750000 | 173 | 1422 | 0.08 | 16或18 |
| 780000 | 176 | 1467 | 0.08 | 16或18 |
| 860000 | 190 | 1575 | 0.08 | 16或18 |
| 1140000 | 237 | 1949 | 0.08 | 16或18 |
| 1170000 | 242 | 1980 | 0.08 | 16或18 |
Manufacturer catalogue values are not a guarantee for a quoted transformer. Model-specific winding, tap, cooling, rated voltage, losses, impedance and test reports must be confirmed. EU large-transformer efficiency assessment requires the applicable peak efficiency index; we review the applicable efficiency requirements for the quoted model.
PROJECT INQUIRY
What helps us review your requirement.
A data sheet or single-line diagram is the best starting point. If some information is missing, send what you have.
- Network duty
- Rated power, voltage ratio, frequency and system fault level
- Operating conditions
- Cooling method, ambient conditions, altitude and installation layout
- Performance targets
- Losses, impedance, sound limits and insulation levels
- Project evidence
- Applicable standards, required tests, inspection points and delivery schedule
Documentation follows the proposed model.
Standards, certificates and test reports vary by manufacturer and configuration. The quotation will identify the proposed manufacturer, applicable documents, inspection scope and agreed delivery terms.
How we review quality and documentation →Ready to discuss your project?
Share your electrical requirements and target schedule with the WEYPLEX project desk.