Glass Insulators

← All product families

08 / 08

Glass Insulators

Toughened glass insulator units for AC and DC overhead lines, selected by mechanical failing load, coupling, profile, creepage distance and the complete string requirements.

Glass Insulators in the supplied manufacturer catalogue

APPLICATION

Specified for the work it needs to do.

Glass insulator selection starts with the line specification and string arrangement. The required mechanical rating, coupling, profile and environmental conditions are reviewed with the proposed manufacturer before a model is quoted.

Common applications

  • Overhead transmission and distribution lines
  • Line construction and maintenance
  • Utility and EPC supply projects

TECHNICAL DATA

Glass insulator model families

Cap-and-pin technical data

Expand a product family to compare models. Dimensions and mechanical ratings use metric units. Electrical test values apply to individual units. A dash indicates an unspecified value.

View numbered profile drawings ↓

IEC standard AC
IEC standard AC
ModelCodeDrawingMinimum failing load (kN)Height (mm)Diameter (mm)Creepage (mm)Locking pinLightning impulse withstand, peak (kV)1 min power-frequency wet withstand (kV)Power-frequency puncture (kV)Unit weight (kg)
LXY-4013120214011017519011R70201102.1
LXY1-4013120514010017519011R70201102.1
LXY2-7013226417012725532016W100401304.0
LXY2-7013226617012725532016R100401304.0
LXY1-7013226017014625532016W100401304.0
LXY1-7013226217014625532016R100401304.0
LXY-100133217110014625532016W100401304.1
LXY-100133219110014625532016R100401304.1
LXY-120134233112014625532016W100401304.2
LXY-120134235112014625532016R100401304.2
LXY-160135079216017028040020R110451306.1
LXY-160135077216017028040020W110451306.1
LXY3-160135071216015528040020R110451306.0
LXY3-160135069216015528040020W110451306.0
LXY4-160135075216014628040020R110451306.0
LXY4-160135073216014628040020W110451306.0
LXY3-210136257221017028040020R110451306.3
LXY4-210136259321017028045020R110451307.0
LXY-240136205-1224017028040024R110451307.1
LXY2-240136215-1324017028045024R110451307.8
LXY3-300137201330019532048524R125501309.5
LXY-420138218442020536056028R1255514013.3
LXY-840139214484030040070040R1356014026.8
IEC anti-fog AC
IEC anti-fog AC
ModelCodeDrawingMinimum failing load (kN)Height (mm)Diameter (mm)Creepage (mm)Locking pinLightning impulse withstand, peak (kV)1 min power-frequency wet withstand (kV)Power-frequency puncture (kV)Unit weight (kg)
LXHY4-7013267567014625540016W120451304.9
LXHY4-7013267867014625540016R120451304.9
LXHY5-7013264837014628045016W125501305.4
LXHY5-7013265037014628045016R125501305.4
LXHY5-7013267157014632055016R130551306.8
LXHY-100133650610014625540016W120451305.0
LXHY-100133651610014625540016R120451305.0
LXHY4-100133633310014628045016W125501305.5
LXHY4-100133635310014628045016R125501305.5
LXHY5-100133644510014632055016R130551306.9
LXHY-120134649612014625540016W120451305.1
LXHY-120134651612014625540016R120451305.1
LXHY4-120134625312014628045016W125501305.6
LXHY4-120134623312014628045016R125501305.6
LXHY5-120134637512014632055016R130551307.0
LXHY5-160135638316015528045020R125501306.7
LXHY5-160135636316015528045020W125501306.7
LXHY4-160135640316017028045020R125501306.7
LXHY4-160135639316017028045020W125501306.7
LXHY5-160135630-1516017032055020R130551308.2
LXHY6-160135629-1516015532055020R130551308.2
LXHY3-210136256521017032055020R130551308.3
LXHY3-240136227624017032055024R130551309.6
LXHY4-300137208630019532055024R1305513010.6
LXHY5-300137234630019536063524R1305513012.7
LXHY-420138219642020536063528R1305513014.8
LXHY-550139217655024036063532R1305513017.5
IEC aerodynamic AC
IEC aerodynamic AC
ModelCodeDrawingMinimum failing load (kN)Height (mm)Diameter (mm)Creepage (mm)Locking pinLightning impulse withstand, peak (kV)1 min power-frequency wet withstand (kV)Power-frequency puncture (kV)Unit weight (kg)
LXAY-70132252-197012738036516R90401305.8
LXAY1-70132253-197014638036516R90401305.8
LXAY-100133625-1910014638036516R90401305.9
LXAY-120134021-1912014638036516R90401306.0
LXAY-160—916014642038020R9045130—
LXAY1-160—916015542038020R9045130—
LXAY2-160—916017042038020R9045130—
LXAY-210—921017042038020R9045130—
LXAY-240136221924017042038024R90451309.2
LXAY-300137211930019545045024R904513011.6
LXAY-420138220942020545045028R955013013.2
IEC outer-rib DC
IEC outer-rib DC
ModelCodeDrawingMinimum failing load (kN)Height (mm)Diameter (mm)Creepage (mm)Locking pinPositive DC 1 min dry withstand (kV)SF6 puncture withstand (kV)Positive DC 1 min wet withstand (kV)Unit weight (kg)
LXWZY-300D1378021330019536056028R1502256013
LXWZY-420D1388021342020536056032R1502256515.1
LXWZY-160T1358021416017032056020R1402105510.2
LXWZY-210T1368031421017032056020R1402105510.5
LXWZY-240T1368041424017032056024R1402105511.0
LXWZY-300T1378031430019536063524R1502256013.7
LXWZY-420T1388041442020538063528R1502256516.6
LXWZY-550T1398021455024038063532R1502256519.0
AC outside-rib glass insulators
AC outside-rib glass insulators listing
ModelCodeDrawingMinimum failing load (kN)Height (mm)Diameter (mm)Creepage (mm)Locking pinLightning impulse withstand, peak (kV)1 min power-frequency wet withstand (kV)Power-frequency puncture (kV)Unit weight (kg)
LXHY4-7013267567014625540016W120451304.9
LXHY4-7013267867014625540016R120451304.9
LXHY5-7013264837014628045016W125501305.4
LXHY5-7013265037014628045016R125501305.4
LXHY5-7013267157014632055016R130551306.8
LXHY-100133650610014625540016W120451305.0
LXHY-100133651610014625540016R120451305.0
LXHY4-100133633310014628045016W125501305.5
LXHY4-100133635310014628045016R125501305.5
LXHY5-100133644510014632055016R130551306.9
LXHY-120134649612014625540016W120451305.1
LXHY-120134651612014625540016R120451305.1
LXHY4-120134625312014628045016W125501305.6
LXHY4-120134623312014628045016R125501305.6
LXHY5-120134637512014632055016R130551307.0
LXHY5-160135638316015528045020R125501306.7
LXHY5-160135636316015528045020W125501306.7
LXHY4-160135640316017028045020R125501306.7
LXHY4-160135639316017028045020W125501306.7
LXHY5-160135630-1516017032055020R130551308.2
LXHY6-160135629-1516015532055020R130551308.2
LXHY3-210136256521017032055020R130551308.3
LXHY3-240136227624017032055024R130551309.6
LXHY4-300137208630019532055024R1305513010.6
LXHY5-300137234630019536063524R1305513012.7
LXHY-420138219642020536063528R1305513014.8
LXHY-550139217655024036063532R1305513017.5
IEC DC
IEC DC
ModelCodeDrawingMinimum failing load (kN)Height (mm)Diameter (mm)Creepage (mm)Locking pinPositive DC 1 min dry withstand (kV)SF6 puncture withstand (kV)Positive DC 1 min wet withstand (kV)Unit weight (kg)
LXZY-1601359021016017032056020R140210558.9
LXZY-2101369021021017032056020R140210559.5
LXZY-2401369031024017032056024R140210559.8
LXZY-3001379171130019538063524R1502256013.0
LXZY1-3001379211030019538069024R1502256014.0
LXZY2-3001379191030019536063524R1502256513.0
LXZY-4201389071142020536056028R1502256513.9
LXZY1-4201389081142020538062028R1502256515.5
LXZY2-4201389141042020536063528R1502256515.5
LXZY2-5501399131055024036063532R1502256518
LXZY-8401399081184030040070040R1702557527.6
LXAZY-1601359031216017042039020R140210608.4
LXAZY-2101369041221017042039020R140210608.9
LXAZY-3001379081230019545045024R1502256011.8
LXAZY-4201389151242020545045028R1502256014.3
IEC ground-wire glass insulators
Ground-wire glass insulators
ModelCodeDrawingMinimum failing load (kN)Height (mm)Diameter (mm)Creepage (mm)MountingPower-frequency puncture (kV)Unit weight (kg)
LXDY-70C1322461670210200220Suspension1304.8
LXDY-70CN1322471770210200220Tension1304.7
LXDY-100C13320616100210200220Suspension1304.8
LXDY-100CN13320717100210200220Tension1304.7
CSA standard profile
CSA standard profile · Ball-and-socket
ModelCSA classCouplingDrawingCombined M&E strength (kN)Impact strength (N·m)Tension proof (kN)Diameter (mm)Spacing (mm)Creepage (mm)Low-frequency dry flashover (kV)Low-frequency wet flashover (kV)Positive critical impulse flashover (kV)Negative critical impulse flashover (kV)Low-frequency puncture (kV)RIV test voltage (kV)Max. RIV at 1 MHz (µV)Net weight (kg)
LXYC-70CS-3Type B18704535255146320805012513013010504.2
LXYC-120CS-5Type J181204560255146320805012513013010504.3
LXYC-160CS-8Type K191604580280146400805012513013010506.4
LXYC1-160CS-8AType K191604580280170400805012513013010506.5
LXYC-220CS-11Type K1922045110280156400805014014013010506.6
LXYC1-220CS-11AType K19220451102801704001005014014013010506.7
LXYC-300CS-13IEC 242030045150320195485955014515014010509.6
LXYC-420CS-14IEC 28214204521036020556010050150160140105013.4
CSA fog profile
CSA fog profile · Ball-and-socket
ModelCSA classCouplingDrawingCombined M&E strength (kN)Impact strength (N·m)Tension proof (kN)Diameter (mm)Spacing (mm)Creepage (mm)Low-frequency dry flashover (kV)Low-frequency wet flashover (kV)Positive critical impulse flashover (kV)Negative critical impulse flashover (kV)Low-frequency puncture (kV)RIV test voltage (kV)Max. RIV at 1 MHz (µV)Net weight (kg)
LXHYC-70CS-3Type B22704535280146450905514014013010505.5
LXHYC-120CS-5Type J221204560280146450905514014013010505.6
LXHYC-160CS-8AType K2216045803201705501006014514513010509.3
LXHYC-220CS-11AType K23220451103201705501006014514513010509.5
LXHYC-300CS-13IEC 24233004515036019563510565150150140105013.5
LXHYC-420CS-14IEC 28234204521036020563510565150150140105014.5
LXHYC-550CS-15IEC 32235504527536024063510565150160140105018.6
Clevis type Profile (CSA classes)
Clevis type Profile (CSA classes)
ModelCSA classDrawingCombined M&E strength (kN)Impact strength (N·m)Tension proof (kN)Diameter (mm)Spacing (mm)Creepage (mm)Low-frequency dry flashover (kV)Low-frequency wet flashover (kV)Positive critical impulse flashover (kV)Negative critical impulse flashover (kV)Low-frequency puncture (kV)RIV test voltage (kV)Max. RIV at 1 MHz (µV)Net weight (kg)
LXHYC1-70CCS-22470453520014622065351151151307.5503.3
LXHYC-70CCS-425704535255146320805012513013010504.3
LXHYC-120CCS-6251204560255146320805012513013010504.5
DC Profile (LXZYC series)
DC Profile (LXZYC series)
ModelCouplingDrawingCombined M&E strength (kN)Impact strength (N·m)Tension proof (kN)Diameter (mm)Spacing (mm)Creepage (mm)DC 1 min dry withstand (±kV)DC 1 min wet withstand (±kV)Dry lightning impulse withstand (kV)DC SF6 puncture withstand (kV)Net weight (kg)
LXZYC-160Type K261604580320170560140551302109.3
LXZYC-220Type K2622045110320170560140551302109.5
LXZYC-240Type K2624045120320170560140551302109.8
LXZYC-300IEC 2426300451503601956351456013522013.6
LXZYC-420IEC 2826420452103602056351506513522514.6
LXZYC-550IEC 3226550452753602406351506513522518.6

For the DC Profile (LXZYC series), the steel material meets Charpy C1 (at −20 °C, ≥20 J). Specify any alternative Charpy requirement when ordering.

ANSI standard profile
ANSI standard profile · Ball-and-socket
ModelANSI classCouplingDrawingCombined M&E strength (kN)Impact strength (N·m)Tension proof (kN)Diameter (mm)Spacing (mm)Creepage (mm)Low-frequency dry flashover (kV)Low-frequency wet flashover (kV)Positive critical impulse flashover (kV)Negative critical impulse flashover (kV)Low-frequency puncture (kV)RIV test voltage (kV)Max. RIV at 1 MHz (µV)Net weight (kg)
LXY-100M52-3-HType B271004550255146320805012513013010504.2
LXY-140M52-5-HType J271404570255146320805012513013010504.3
LXY-180M52-8-HType K281804590280146400805012513013010506
LXY-220M52-11Type K2822045110280156400805014014013010507
ANSI standard profile · Additional ball-and-socket models
ModelCouplingDrawingCombined M&E strength (kN)Impact strength (N·m)Tension proof (kN)Diameter (mm)Spacing (mm)Creepage (mm)Low-frequency dry flashover (kV)Low-frequency wet flashover (kV)Positive critical impulse flashover (kV)Negative critical impulse flashover (kV)Low-frequency puncture (kV)RIV test voltage (kV)Max. RIV at 1 MHz (µV)Net weight (kg)
LXY3-300IEC 242930045150320195485955014515014010509.5
LXY-420IEC 28304204521036020556010050150160140105013.4
ANSI fog profile
ANSI fog profile · Ball-and-socket
ModelCouplingDrawingCombined M&E strength (kN)Impact strength (N·m)Tension proof (kN)Diameter (mm)Spacing (mm)Creepage (mm)Low-frequency dry flashover (kV)Low-frequency wet flashover (kV)Positive critical impulse flashover (kV)Negative critical impulse flashover (kV)Low-frequency puncture (kV)RIV test voltage (kV)Max. RIV at 1 MHz (µV)Net weight (kg)
LXHY-100MType B311004550280146450905514014013010505.5
LXHY-140MType J311404570280146450905514014013010505.6
LXHY-180MType K3118045903201605501006014514513010509.3
LXHY-220MType K32220451103201705501006014514513010509.5
LXHY5-300IEC 24323004515036019563510565150150140105013.5
LXHY-420IEC 28324204521036020563510565150150140105014.5
LXHY-550IEC 32325504527536024063510565150160140105018.6
Clevis type Profile (ANSI classes)
Clevis type Profile (ANSI classes)
ModelANSI classDrawingCombined M&E strength (kN)Impact strength (N·m)Tension proof (kN)Diameter (mm)Spacing (mm)Creepage (mm)Low-frequency dry flashover (kV)Low-frequency wet flashover (kV)Positive critical impulse flashover (kV)Negative critical impulse flashover (kV)Low-frequency puncture (kV)RIV test voltage (kV)Max. RIV at 1 MHz (µV)Net weight (kg)
LXY1-70CM52-23370453520014622065351151151307.5503.3
LXY-100CM52-4-H341004550255146320805012513013010504.3
LXY-140CM52-6-H341404570255146320805012513013010504.5
DC Profile (LXZY and LXZY2 series)
DC Profile (LXZY and LXZY2 series)
ModelCouplingDrawingCombined M&E strength (kN)Impact strength (N·m)Tension proof (kN)Diameter (mm)Spacing (mm)Creepage (mm)DC 1 min dry withstand (±kV)DC 1 min wet withstand (±kV)Dry lightning impulse withstand (kV)DC SF6 puncture withstand (kV)Net weight (kg)
LXZY-180MType K351804590320160560140551302109.2
LXZY-220MType K3522045110320170560140551302109.5
LXZY2-300IEC 2435300451503601956351405513021013.6
LXZY2-420IEC 2835420452103602056351456013522014.6
LXZY2-550IEC 3235550452753602406351506513522518.6
Numbered profile drawings 1–35
Glass insulator numbered profile drawings, set 1
Glass insulator numbered profile drawings, set 2
Glass insulator numbered profile drawings, set 3
Glass insulator numbered profile drawings, set 4
Glass insulator numbered profile drawings, set 5
Glass insulator numbered profile drawings, set 6
Glass insulator numbered profile drawings, set 7
Glass insulator numbered profile drawings, set 8
Glass insulator numbered profile drawings, set 9

TESTING & DOCUMENTATION

Clear references. Model-specific reports.

CNAS laboratory recognition

Our manufacturing partner operates a CNAS-accredited laboratory. We confirm the accredited test scope for the proposed insulator.

KEMA / VEIKI cooperation

Our manufacturing partner has worked with KEMA in the Netherlands and VEIKI in Hungary on testing. We match the applicable reports to the proposed model during quotation.

Unit and string checks

Specify mechanical failing load, coupling size, creepage distance, AC or DC duty and site conditions. Agree the applicable type, sample and routine tests and required acceptance documents.

European references in the manufacturer catalogue

The catalogue lists an Irish transmission-line reference and a UK overhead-line equipment supply framework. It does not state the unit models, quantities or dates for these entries. A framework reference is not proof of a completed installation.

View manufacturer references →

PROJECT INQUIRY

What helps us review your requirement.

A specification or dimensioned drawing is the best starting point. If some information is missing, send what you have.

Line specification
AC or DC duty, system voltage, string arrangement and utility requirements.
Mechanical requirements
Specified mechanical rating, coupling standard, unit spacing and dimensions.
Insulation and environment
Creepage distance, pollution, altitude, temperature and required shed profile.
Project documentation
Required standards, test reports, inspection arrangements and acceptance criteria.
Supply scope
Quantity, fittings or accessories, packing, destination and delivery schedule.

Documentation follows the proposed model.

WEYPLEX coordinates the inquiry with the proposed manufacturer. The quotation identifies the model, configuration, applicable documents, inspection scope and delivery terms. Pricing is project-specific.

The line specification and coupling requirements must be confirmed before selecting an insulator or string arrangement.

How we review quality and documentation →

Ready to discuss your project?

Share your specification, drawing and target schedule with the WEYPLEX project desk.

Get a Project Quote
Scroll to Top