Dry-Type Transformers

← All product families

03 / 08

Dry-Type Transformers

For indoor electrical distribution where enclosure, ventilation, sound and fire-safety requirements shape the installation.

Red dry-type transformer assembly

APPLICATION

Specified for the work it needs to do.

Dry-type transformer selection depends on the building and load as much as the rating. We coordinate technical requirements with the proposed manufacturing partner and confirm the requested model documentation.

Common applications

  • Data centers and critical facilities
  • Commercial buildings
  • Industrial plants and infrastructure

PRODUCT CAPABILITIES

Dry-type families in the archive.

Our manufacturing partners offer resin-insulated SC(B)12, SC(B)14 and SC(B)18 6/10 kV families from 30 to 2,500 kVA; a 20 kV SC(B)12/18 family from 50 to 2,500 kVA; and a 35/0.4 kV SC(B)10 family from 50 to 2,500 kVA. The range also includes an SCZ(B)10 on-load tap-changing family.

6/10 kVSC(B)12 / 14 / 18 resin-insulated families
20 kVSC(B)12 / 18 dry-type family
35/0.4 kVSC(B)10 family

Compare model-specific loss values in the tables below. A current signed data sheet and test report are still needed before making a model-specific EU or U.S. efficiency claim.

MANUFACTURER CATALOGUE TABLES

Dry-type transformer technical data

Catalogue rows cover 6/10 kV resin-insulated and amorphous-core series, plus 20 kV dry-type series. Expand a series to compare capacity, losses, impedance and acoustic figures.

SC(B)18 6kV, 10kV18 ratings · click to view

Catalogue loss figures are shown as published at the stated 75 °C reference. HV voltage options, tapping arrangement and vector group vary by model; confirm these in the quoted data sheet.

kVANo-load loss WLoad loss W at 75 °CImpedance %Sound pressure dB(A)
30105555444
50155785444
802101080445
1002301235445
1252701450446
1603101670446
2003601990447
2504152170447
3155102735448
4005703140448
5006703835449
6307504695650
8008755475651
100010206430652
125012057610653
160014159230653
2000176011420654
2500208013540654
SC(B)14 6kV, 10kV18 ratings · click to view

Catalogue loss figures are shown as published at the stated 75 °C reference. HV voltage options, tapping arrangement and vector group vary by model; confirm these in the quoted data sheet.

kVANo-load loss WLoad loss W at 75 °CImpedance %Sound pressure dB(A)
30130555444
50185785444
802501080445
1002701235445
1253201450446
1603651670446
2004201990447
2504902170447
3156002735448
4006653140448
5007903835449
6308854695650
80010355475651
100012006430652
125014207610653
160016659230653
2000207511420654
2500245013540654
SC(B)12 6kV, 10kV18 ratings · click to view

Catalogue loss figures are shown as published at the stated 75 °C reference. HV voltage options, tapping arrangement and vector group vary by model; confirm these in the quoted data sheet.

kVANo-load loss WLoad loss W at 75 °CImpedance %Sound pressure dB(A)
30150620444
50215870444
802951200445
1003201370445
1253751610446
1604301860446
2004952200447
2505752410447
3157053030448
4007853480448
5009304260449
63010405200650
80012156070651
100014157090652
125016708460653
1600196010240653
2000244012610654
2500288014990654
SCZ(B)10 6kV, 10kV13 ratings · click to view

Catalogue loss figures are shown as published at the stated 75 °C reference. HV voltage options, tapping arrangement and vector group vary by model; confirm these in the quoted data sheet.

kVANo-load loss WLoad loss W at 75 °CImpedance %Sound pressure dB(A)
2006402250447
2507352450447
3159903150448
40011203730448
50012904560449
63014905390450
63014405550650
80017106550651
100019807670652
125023409080653
1600272010830653
2000342013280654
2500396015810654
SC(B)10 35 0.4 kV17 ratings · click to view

Catalogue loss figures are shown as published at the stated 75 °C reference. HV voltage options, tapping arrangement and vector group vary by model; confirm these in the quoted data sheet.

kVANo-load loss WLoad loss W at 75 °CImpedance %Sound pressure dB(A)
504501240650
806001540650
1006301820651
1256702310651
1607902450651
2008802900651
2509903320651
31511703940651
40013704720651
50016205810652
63018606720652
80021607970652
100024309080652
1250283011090653
1600324013450653
2000382015900654
2500445019040655
SCBH19 Amorphous Alloy Core13 ratings · click to view

Catalogue loss figures are shown as published at the stated 75 °C reference. HV voltage options, tapping arrangement and vector group vary by model; confirm these in the quoted data sheet.

kVANo-load loss WLoad loss W at 75 °CImpedance %Sound pressure dB(A)
1601201670453
2001401990453
2501602170453
3151952730453
4002153140453
5002503830455
6302904690655
8003355470655
10003856430658
12504557610658
16005309230658
200070011420662
250084013540662
SCBH17 Amorphous Alloy Core13 ratings · click to view

Catalogue loss figures are shown as published at the stated 75 °C reference. HV voltage options, tapping arrangement and vector group vary by model; confirm these in the quoted data sheet.

kVANo-load loss WLoad loss W at 75 °CImpedance %Sound pressure dB(A)
1601451670453
2001701990453
2501952170453
3152352730453
4002653140453
5003053830455
6303504690655
8004105470655
10004706430658
12505507610658
16006459230658
200085011420662
2500102013540662
SCBH15 Amorphous Alloy Core13 ratings · click to view

Catalogue loss figures are shown as published at the stated 75 °C reference. HV voltage options, tapping arrangement and vector group vary by model; confirm these in the quoted data sheet.

kVANo-load loss WLoad loss W at 75 °CImpedance %Sound pressure dB(A)
1601701850453
2002002210453
2502302410453
3152803040453
4003102490453
5003604260455
6304105220655
8004806080655
10005507140658
12506508460658
160076010260658
2000100012690662
2500120015040662
SC(B)18 · 20 kV15 ratings · click to view

20/0.4 kV; Dyn11 for this series. Load loss is given at 120 °C for insulation class F and 145 °C for class H.

kVANo-load loss WLoad loss W · FLoad loss W · HImpedance %
50235111011806
100375179019206
160460222023806
200500265028306
250570308032906
315660367039206
400785436046606
500920521055706
6301045616065906
8001200743079606
10001420880093606
1250162510400111006
1600191012400133006
2000221514700158006
2500265017400186006
SC(B)14 · 20 kV15 ratings · click to view

20/0.4 kV; Dyn11 for this series. Load loss is given at 120 °C for insulation class F and 145 °C for class H.

kVANo-load loss WLoad loss W · FLoad loss W · HImpedance %
50260111011806
100415179019206
160510222023806
200555265028306
250635308032906
315735367039206
400875436046606
5001025521055706
6301160616065906
8001330743079606
10001575880093606
1250180510400111006
1600212012400133006
2000246014700158006
2500294517400186006
SC(B)12 · 20 kV15 ratings · click to view

20/0.4 kV; Dyn11 for this series. Load loss is given at 120 °C for insulation class F and 145 °C for class H.

kVANo-load loss WLoad loss W · FLoad loss W · HImpedance %
50275123013106
100435199021306
160535247026406
200585294031406
250670342036606
315775408043606
400920484051806
5001080579061906
6301220684073206
8001400826088406
100016609780104006
1250190011500123006
1600223013800148006
2000259016300175006
2500310019300207006

The 35/10 kV sheet is excluded pending confirmation of inconsistent loss units in its header and values. These are legacy manufacturer tables, not current signed model data sheets. EU Tier 2 or U.S. DOE efficiency status cannot be inferred from the tables alone; confirm voltage, frequency, temperature reference and test basis for the actual quote.

PROJECT INQUIRY

What helps us review your requirement.

A data sheet or single-line diagram is the best starting point. If some information is missing, send what you have.

Load profile
Capacity, voltage, frequency and expected load variation
Installation
Enclosure, clearances, ventilation and ambient temperature
Performance
Losses, impedance, sound limits and insulation class
Project evidence
Applicable IEC or IEEE specification and requested test reports

Documentation follows the proposed model.

Standards, certificates and test reports vary by manufacturer and configuration. The quotation will identify the proposed manufacturer, applicable documents, inspection scope and agreed delivery terms.

How we review quality and documentation →